Change that old noisy bath fan with one that's whisper peaceful and clears the air faster with much better airflow. You typically can do it in less than a day with little or no ceiling repair. By the Do It Yourself specialists of The Family Handyman Publication, You might likewise like: TBDTime A complete day, Intricacy Intermediate, Cost $101250 Strategy the bath exhaust fan replacement, A new generation of efficient and peaceful exhaust fans is now offered in the house centers and from heating, ventilation and a/c providers.
See "Shopping for a Peaceful Fan," below, for more details. In this article, we'll show you how to eliminate an old bath fan and install a new quiet one.
While we're at it, we'll show you how to replace normal 3-in. This project involves electrical wiring, so call your local electrical inspector to find out if you need an authorization. Setting up a fan needs only elementary woodworking and electrical abilities.
If you face problems you can't handle, such as complicated electrical circuitry, tight duct clearances, water damage at the roofing system vent cap or a high roofing system pitch, do not think twice to call a certified electrical expert. You'll need to go into your attic and stroll on your roof, so play it safe.
While on the roofing, use roof brackets, roofing system cleats or a security harness for safe footing and fall defense. And if your roofing is too high or you do not feel great up there, work with a pro for this part. The bath fan we're changing is fairly common. It's situated in a ceiling with an available incomplete attic above.
If your old fan system has extra features like a light or heating system that operates off a 2nd switch, your electrical wiring will be more complicated. If you have a 2nd floor above the fan, determine the height of the space readily available.
While it must fit into normal floor joist space, examine the fan measurements to make sure. If you do not have an attic above, as we reveal, you'll have to do the whole installation from listed below.
Changing to a bigger wall vent cap can be more complex if you have brick, stucco or vinyl siding rather than wood. If you're not sure how to continue, check with a siding specialist for guidance. Remove the old fan, Picture 1: Pull out the old motor assembly, Shut off the power at the main panel.
With the fan running, flip circuit breakers or loosen merges till it stops. Put on your safety goggles. As you take down and snap off the old grille, see out for falling debris! You 'd be impressed at how much waste can spill out. Disconnect the motor and remove it from the real estate (Picture 1).
To make it simpler to operate in the attic, discover a little piece of plywood to kneel or lie onapproximately 2 x 3 ft. In the summer, operate in the early morning. Attics fume on warm days. Press the insulation back from the old fan real estate and remove the housing (Picture 3).
Table of Contents
Latest Posts
How To Install A Bathroom Fan In Outside Wall in Ottawa
How To Install Landscape Path Lighting
Commercial Bathroom Exhaust Fan With Heater
All Categories
Navigation
Latest Posts
How To Install A Bathroom Fan In Outside Wall in Ottawa
How To Install Landscape Path Lighting
Commercial Bathroom Exhaust Fan With Heater